Aerogel Insulation Installs Faster
and Saves Costs on Large Vessel
Thinner aerogel is easier to store, handle, and install than cellular glass — with equal thermal performance
|



|
Challenges
- Replace specified cellular glass insulation with Aspen Aerogels insulation on one complete vessel including heads.
- Vessel was 20 ft (6.1 m) long and 12 ft (3.7 m) wide.
- Work was executed outdoors on an elevated equipment platform within a chemical facility.
- Weather conditions were overcast with intermittent light rain.
Aerogel Solution
- A single 0.24 in (6 mm) layer of Pyrogel® 6350 was used instead of the specified 1.5 in (38 mm) thick cellular glass.
- Large sections of Pyrogel 6350 blanket were wrapped completely around the vessel, instead of small cellular glass blocks.
- The installation required only a tape measure, box cutter knife, and straight edge.
Benefits
- The vessel was insulated with Pyrogel 6350 in one third as much time as cellular glass.
- Because installing aerogel blankets doesn’t require access to the entire vessel, scaffolding costs were reduced 25%-50%.
- Installers did not need any shop equipment; all aerogel sections were cut from a roll on the vessel platform.
- Pyrogel 6350’s compact roll reduced shipping, handling, waste, and storage costs compared to boxes of cellular glass.
- Rain did not halt work, since aerogel insulation is hydrophobic and did not have to be covered.
|
|
| How the Vessel Was Insulated
|
1. |
 |
| Less than one roll of Pyrogel 6350 was needed to insulate the entire vessel. All work was done on the vessel platform. |
|
2. |
 |
| The material was cut to the outside circumference of the vessel and wrapped around in one complete blanket. |
|
3. |
 |
| The material was secured at the bottom only with the adhesive insulation pins. |
|
4. |
 |
| For the vessel heads, the material was cut into pie sections and attached with adhesive insulation pins at each end. |
|
5. |
 |
| After the large pie sections were installed, smaller sections were made to accommodate the ends. |

|
6. |
 |
| Completed insulated vessel with Pyrogel 6350 aerogel thermal insulation. |
|
|